1.
Chinese Journal of Radiological Medicine and Protection ; (12): 685-690, 2022.
Article in Chinese | WPRIM | ID: wpr-956845

ABSTRACT

Objective:To study the impact of the Varian real-time position management (RPM) respiratory gating system on radiotherapy planning dosimetry.Methods:The radiotherapy plans of 40 cases with thoracic or abdominal tumors were retrospectively selected in this study. The motion phantom for quality control was adopted to generate respiratory gating signals, and the 30%-60% stable phase at the end of expiratory was selected as the respiratory gating window. The dose verification for the abovementioned radiotherapy plans was performed using the Portal Dosimetry (PD) system under RPM respiratory gating mode with the Edge accelerator. Afterwards, dose analysis was performed with different γ passing rate criteria and the distribution characteristics of γ values were analyzed. Finally, the verification results between the non-gating mode and the gating mode were compared.Results:Under the respiratory gating mode, the passing rates of all intensity-modulated radiation therapy/volumetric-modulated arc therapy (IMRT/VMAT) plans with or without flattening filters were over 95.5% by γ criteria of (3%, 3 mm) or (3%, 2 mm) and were over 90% by stricter γ criteria of (2%, 2 mm). All plans met the clinical requirements recommended by the American Association of Physicists in Medicine (AAPM). The passing rates of dose verification under non-gating mode were slightly better than those under respiratory gating mode, and the differences between the two modes were statistically significant (3%/3 mm, Z =-1.45; 3%/2 mm, Z =-2.86; 2%/2 mm, Z =-3.70; 1%/1 mm, Z =-4.52; P<0.05). There was no significant difference in the minimum and maximum values of γ and the share of γ > 1.5 of plan verification result under the two modes. However, the average value and standard deviation of the γ were generally smaller under the non-gating mode. Conclusions:The impact of the introduction of RPM respiratory gating technology on dose is clinically acceptable, and the execution of these plans in this gating mode is safe and reliable.

2.
Radiation Oncology Journal ; : 84-94, 2014.
Article in English | WPRIM | ID: wpr-12509

ABSTRACT

PURPOSE: To quantify the cardiac dose reduction during breathing adapted radiotherapy using Real-time Position Management (RPM) system in the treatment of left-sided breast cancer. MATERIALS AND METHODS: Twenty-two patients with left-sided breast cancer underwent CT scans during breathing maneuvers including free breathing (FB), deep inspiration breath-hold (DIBH), and end inspiration breath-hold (EIBH). The RPM system was used to monitor respiratory motion, and the in-house self respiration monitoring (SRM) system was used for visual feedback. For each scan, treatment plans were generated and dosimetric parameters from DIBH and EIBH plans were compared to those of FB plans. RESULTS: All patients completed CT scans with different breathing maneuvers. When compared with FB plans, DIBH plans demonstrated significant reductions in irradiated heart volume and the heart V25, with the relative reduction of 71% and 70%, respectively (p < 0.001). EIBH plans also resulted in significantly smaller irradiated heart volume and lower heart V25 than FB plans, with the relative reduction of 39% and 37%, respectively (p = 0.002). Despite of significant expansion of lung volume using inspiration breath-hold, there were no significant differences in left lung V25 among the three plans. CONCLUSION: In comparison with FB, both DIBH and EIBH plans demonstrated a significant reduction of radiation dose to the heart. In the training course, SRM system was useful and effective in terms of positional reproducibility and patient compliance.


Subject(s)
Humans , Breast Neoplasms , Cardiac Volume , Feedback, Sensory , Heart , Lung , Patient Compliance , Radiotherapy , Respiration , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL